File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

이덕중

Lee, Deokjung
Computational Reactor physics & Experiment Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.conferencePlace US -
dc.citation.conferencePlace San Francisco -
dc.citation.endPage 1125 -
dc.citation.startPage 1119 -
dc.citation.title 2016 International Congress on Advances in Nuclear Power Plants, ICAPP 2016 -
dc.citation.volume 2 -
dc.contributor.author Zheng, Youpi -
dc.contributor.author Lee, Deokjung -
dc.contributor.author Zhang, Peng -
dc.contributor.author Lee, Eunki -
dc.contributor.author Shin, Hocheol -
dc.date.accessioned 2023-12-19T21:06:46Z -
dc.date.available 2023-12-19T21:06:46Z -
dc.date.created 2016-09-23 -
dc.date.issued 2016-04-17 -
dc.description.abstract This paper describes the verification of ex-core detector response calculation using Monte-Carlo code. The calculations were performed on a typical commercial PWR core Kori unit 1 in South Korea. The weighting factors of ex-core detector were evaluated through solving the multi-group adjoint equation. The deterministic SN code DORT and Monte-Carlo code MCNP6 were used and compared based on the same BUGLE96 47g cross section library. The results proves the feasibility of using MCNP to calculate the weighting function of ex-core detector. And, it shows the benefit of using Monte-Carlo modeling and simulation in this problem. Two aspects are concluded. First, the adjoint calculation in the radial geometry suffers strong ray effect while using SN method. It is well overcome by the Monte- Carlo calculation. Secondly, the geometry approximation is an inevitable effect. The powerful modeling capability of Monte-Carlo code shows obvious improvement for the ex-core response calculation. -
dc.identifier.bibliographicCitation 2016 International Congress on Advances in Nuclear Power Plants, ICAPP 2016, v.2, pp.1119 - 1125 -
dc.identifier.isbn 978-151082594-9 -
dc.identifier.scopusid 2-s2.0-84986300647 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/36884 -
dc.language 영어 -
dc.publisher 2016 International Congress on Advances in Nuclear Power Plants, ICAPP 2016 -
dc.title Ex-core detector response evaluation of kori 1 reactor using mcnp6 adjoint calculation -