File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

신흥주

Shin, Heungjoo
Micro/Nano Integrated Systems Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.conferencePlace US -
dc.citation.conferencePlace Las Vegas, NV -
dc.citation.endPage 1070 -
dc.citation.startPage 1068 -
dc.citation.title 30th IEEE International Conference on Micro Electro Mechanical Systems, MEMS 2017 -
dc.contributor.author Seo, Junyoung -
dc.contributor.author Lim, Yeongjin -
dc.contributor.author Shin, Heungjoo -
dc.date.accessioned 2023-12-19T19:36:50Z -
dc.date.available 2023-12-19T19:36:50Z -
dc.date.created 2016-11-01 -
dc.date.issued 2017-01-22 -
dc.description.abstract This paper reports a novel hydrogen sensor based on an array of single suspended carbon nanowires (Φ ∼ 200 nm, length ∼ 100 μm) decorated with various sizes (10 ∼ 50 nm) of Pd nanoparticles; this H2 sensor exhibits advantageous sensor performances such as room temperature sensing with high sensitivity, wide sensing range, and full recovery in 5 s via low power consumption (30 μW). These high performances are enabled by the novel architecture of suspended Pd nanoparticles/carbon nanowires facilitating enhanced mass transfer, high surface area to volume ratio, and good thermal insulation. This novel sensor platform can be fabricated using only simple batch microfabrication processes including carbon-MEMS that consisted UV-lithography and pyrolysis. The sensitivity and sensing range of the H2 sensor can be modulated by controlling the size of Pd nanoparticles (10-30 nm Pd nanoparticles: 2.51%/ppm1/2 and 10-7,000 ppm, 30-50 nm Pd nanoparticles: 0.36 %/ppm1/2 and 10 ppm-5 %). Hence, wide range of H2 sensing was enabled by integrating nanowires decorated with various Pd nanoparticles on a chip. Moreover, the gas response can be fully recovered in a very short time (e.g. 5 s for 1,000 ppm H2) by self-heating at a carbon nanowire. -
dc.identifier.bibliographicCitation 30th IEEE International Conference on Micro Electro Mechanical Systems, MEMS 2017, pp.1068 - 1070 -
dc.identifier.doi 10.1109/MEMSYS.2017.7863597 -
dc.identifier.issn 1084-6999 -
dc.identifier.scopusid 2-s2.0-85015735372 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/35346 -
dc.identifier.url http://ieeexplore.ieee.org/document/7863597/ -
dc.language 영어 -
dc.publisher 30th IEEE International Conference on Micro Electro Mechanical Systems, MEMS 2017 -
dc.title High-performance hydrogen sensor based on an array of single suspended carbon nanowires selectively functionalized with palladium nanoparticles -
dc.type Conference Paper -
dc.date.conferenceDate 2017-01-22 -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.