File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 184 -
dc.citation.number 3 -
dc.citation.startPage 177 -
dc.citation.title INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY -
dc.citation.volume 22 -
dc.contributor.author Kim, Hyungmin -
dc.contributor.author Chiu, Alan -
dc.contributor.author Park, Shinsuk -
dc.contributor.author Yoo, Seung-Schik -
dc.date.accessioned 2023-12-22T04:44:17Z -
dc.date.available 2023-12-22T04:44:17Z -
dc.date.created 2013-06-24 -
dc.date.issued 2012-09 -
dc.description.abstract The spatial specificity and controllability of focused ultrasound (FUS), in addition to its ability to modify the excitability of neural tissue, allows for the selective and reversible neuromodulation of the brain function, with great potential in neurotherapeutics. Intraoperative magnetic resonance imaging (MRI) guidance has limitations due to its complicated examination logistics, such as fixation through skull screws to mount the stereotactic frame, simultaneous sonication in the MRI environment, and restrictions in choosing MR-compatible materials. To overcome these limitations, an image-guidance system based on optical tracking and preoperative imaging data is developed, separating the imaging acquisition for guidance and sonication procedure for treatment. Techniques to define the local coordinates of the focal point of sonication are presented. First, mechanical calibration detects the concentric rotational motion of a rigid-body optical tracker, attached to a straight rod mimicking the sonication path, pivoted at the virtual FUS focus. The spatial error presented in the mechanical calibration was compensated further by MRI-based calibration, which estimates the spatial offset between the navigated focal point and the ground-truth location of the sonication focus obtained from a temperature-sensitive MR sequence. MRI-based calibration offered a significant decrease in spatial errors (1.9 +/- 0.8 mm; 57% reduction) compared to the mechanical calibration method alone (4.4 +/- 0.9 mm). Using the presented method, pulse-mode FUS was applied to the motor area of the rat brain, and successfully stimulated the motor cortex. The presented techniques can be readily adapted for the transcranial application of FUS to intact human brain. -
dc.identifier.bibliographicCitation INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, v.22, no.3, pp.177 - 184 -
dc.identifier.doi 10.1002/ima.22020 -
dc.identifier.issn 0899-9457 -
dc.identifier.scopusid 2-s2.0-84864997681 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/3179 -
dc.identifier.url http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84864997681 -
dc.identifier.wosid 000307501500005 -
dc.language 영어 -
dc.publisher WILEY-BLACKWELL -
dc.title Image-guided navigation of single-element focused ultrasound transducer -
dc.type Article -
dc.relation.journalWebOfScienceCategory Engineering, Electrical & Electronic; Optics; Imaging Science & Photographic Technology -
dc.relation.journalResearchArea Engineering; Optics; Imaging Science & Photographic Technology -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor focused ultrasound -
dc.subject.keywordAuthor image-guidance -
dc.subject.keywordAuthor optical tracking -
dc.subject.keywordAuthor calibration -
dc.subject.keywordAuthor neuromodulation -
dc.subject.keywordAuthor brain -
dc.subject.keywordAuthor single-element transducer -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.