File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

조형준

Cho, Hyungjoon
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 1381 -
dc.citation.number 5 -
dc.citation.startPage 1369 -
dc.citation.title JOURNAL OF MAGNETIC RESONANCE IMAGING -
dc.citation.volume 51 -
dc.contributor.author Jin, Seokha -
dc.contributor.author Han, SoHyun -
dc.contributor.author Stoyanova, Radka -
dc.contributor.author Ackerstaff, Ellen -
dc.contributor.author Cho, HyungJoon -
dc.date.accessioned 2023-12-21T17:39:49Z -
dc.date.available 2023-12-21T17:39:49Z -
dc.date.created 2019-11-18 -
dc.date.issued 2020-05 -
dc.description.abstract Background The manual segmentation of intact blood-brain barrier (BBB) regions in the stroke brain is cumbersome, due to the coexistence of infarction, large blood vessels, ventricles, and intact BBB regions, specifically in areas with weak signal enhancement following contrast agent injection. Hypothesis That from dynamic susceptibility contrast (DSC)-MRI alone, without user intervention, regions of weak BBB damage can be segmented based on the leakage-related parameter K-2 and the extent of intact BBB regions, needed to estimate K-2 values, determined. Study Type Feasibility. Animal Model Ten female Sprague-Dawley rats (SD, 200-250g) underwent 1-hour middle carotid artery occlusion (MCAO) and 1-day reperfusion. Two SD rats underwent 1-hour MCAO with 3-day and 5-day reperfusion. Field Strength/Sequence 7T; ADC and T-1 maps using diffusion-weighted echo planar imaging (EPI) and relaxation enhancement (RARE) with variable repetition time (TR), respectively. dynamic contrast-enhanced (DCE)-MRI using FLASH. DSC-MRI using gradient-echo EPI. Assessment Constrained nonnegative matrix factorization (cNMF) was applied to the dynamic Delta R2*-curves of DSC-MRI (<4 min) in a BBB-disrupted rat model. Areas of voxels with intact BBB, classified by automated cNMF analyses, were then used in estimating K-1 and K-2 values, and compared with corresponding values from manually-derived areas. Statistical Tests Mean +/- standard deviation of Delta T-1-differences between ischemic and healthy areas were displayed with unpaired Student's t-tests. Scatterplots were displayed with slopes and intercepts and Pearson's r values were evaluated between K-2 maps obtained with automatic (cNMF)- and manually-derived regions of interest (ROIs) of the intact BBB region. Results Mildly BBB-damaged areas (indistinguishable from DCE-MRI (10 min) parameters) were automatically segmented. Areas of voxels with intact BBB, classified by automated cNMF, matched closely the corresponding, manually-derived areas when respective areas were used in estimating K-2 maps (Pearson's r = 0.97, 12 slices). Data Conclusion Automatic segmentation of short DSC-MRI data alone successfully identified areas with intact and compromised BBB in the stroke brain and compared favorably with manual segmentation. Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019. -
dc.identifier.bibliographicCitation JOURNAL OF MAGNETIC RESONANCE IMAGING, v.51, no.5, pp.1369 - 1381 -
dc.identifier.doi 10.1002/jmri.26949 -
dc.identifier.issn 1053-1807 -
dc.identifier.scopusid 2-s2.0-85074571544 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/31123 -
dc.identifier.url https://onlinelibrary.wiley.com/doi/full/10.1002/jmri.26949 -
dc.identifier.wosid 000492523400001 -
dc.language 영어 -
dc.publisher John Wiley & Sons Inc. -
dc.title Pattern recognition analysis of dynamic susceptibility contrast (DSC)-MRI curves automatically segments tissue areas with intact blood-brain barrier in a rat stroke model: A feasibility and comparison study -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Radiology, Nuclear Medicine & Medical Imaging -
dc.relation.journalResearchArea Radiology, Nuclear Medicine & Medical Imaging -
dc.type.docType Article; Early Access -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor pattern-recognition -
dc.subject.keywordAuthor stroke model -
dc.subject.keywordAuthor BBB damage -
dc.subject.keywordAuthor DSC-MRI -
dc.subject.keywordPlus VASCULAR-PERMEABILITY -
dc.subject.keywordPlus DCE-MRI -
dc.subject.keywordPlus VOLUME -
dc.subject.keywordPlus FLOW -
dc.subject.keywordPlus T-1 -
dc.subject.keywordPlus GLIOMA -
dc.subject.keywordPlus MAPS -
dc.subject.keywordPlus FOCAL CEREBRAL-ISCHEMIA -
dc.subject.keywordPlus TURBO-SPIN-ECHO -
dc.subject.keywordPlus ENHANCED MRI -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.