File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

조경화

Cho, Kyung Hwa
Water-Environmental Informatics Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 77 -
dc.citation.startPage 66 -
dc.citation.title JOURNAL OF MEMBRANE SCIENCE -
dc.citation.volume 576 -
dc.contributor.author Park, Jongkwan -
dc.contributor.author Jeong, Kwanho -
dc.contributor.author Baek, Sangsoo -
dc.contributor.author Park, Sanghun -
dc.contributor.author Ligaray, Mayzonee -
dc.contributor.author Chong, Tzyy Haur -
dc.contributor.author Cho, Kyung Hwa -
dc.date.accessioned 2023-12-21T19:16:13Z -
dc.date.available 2023-12-21T19:16:13Z -
dc.date.created 2019-02-21 -
dc.date.issued 2019-04 -
dc.description.abstract Many numerical models for membrane filtration have been developed to explain and predict fouling mechanisms. The models can simulate flux decline, transmembrane pressure increase, and fouling thickness based on theoretical equations. However, the simulated fouling layer thicknesses have not been validated by in-situ observations on membrane surfaces because the membrane system is operated under a sealed and pressurized condition. In this study, humic acid fouling layers on nanofiltration and reverse osmosis membranes were monitored in-situ and in real-time using optical coherence tomography (OCT). The OCT system detected fouling layer growth over time, and showed that the compact and thick fouling layer had an estimated thickness of 80 mu m. When comparing the thickness of the fouling layer between OCT and scanning electron microscopy (SEM) images, the OCT images showed values that were approximately 8 times higher than those of the SEM images. By comparing the obtained fouling thickness values with the estimated results, two existing models (Faridirad model and pore blockage-cake filtration model) were validated in terms of root mean square error (RMSE), Akaike Information Criteria (AIC), and coefficient of determination (R-2). Both models showed similar high R-2 (>= 0.97) and low RMSE (< 10(-5)) values, but the pore blockage-cake filtration model had lower AIC values than the Faridirad model. This study highlighted that the in-situ and real-time monitoring of fouling thickness can provide significant information for developing an accurate and precise membrane model. -
dc.identifier.bibliographicCitation JOURNAL OF MEMBRANE SCIENCE, v.576, pp.66 - 77 -
dc.identifier.doi 10.1016/j.memsci.2019.01.031 -
dc.identifier.issn 0376-7388 -
dc.identifier.scopusid 2-s2.0-85060478499 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/26429 -
dc.identifier.url https://www.sciencedirect.com/science/article/pii/S0376738818323986?via%3Dihub -
dc.identifier.wosid 000457975100008 -
dc.language 영어 -
dc.publisher Elsevier BV -
dc.title Modeling of NF/RO membrane fouling and flux decline using real-time observations -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Engineering, Chemical; Polymer Science -
dc.relation.journalResearchArea Engineering; Polymer Science -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor Membrane fouling model -
dc.subject.keywordAuthor Optical coherence tomography -
dc.subject.keywordAuthor Real time fouling monitoring -
dc.subject.keywordAuthor High pressure driven membrane -
dc.subject.keywordAuthor Fouling layer thickness -
dc.subject.keywordPlus REVERSE-OSMOSIS MEMBRANES -
dc.subject.keywordPlus ORGANIC-MATTER -
dc.subject.keywordPlus NANOFILTRATION MEMBRANES -
dc.subject.keywordPlus WATER-TREATMENT -
dc.subject.keywordPlus MECHANISMS -
dc.subject.keywordPlus FILTRATION -
dc.subject.keywordPlus ULTRAFILTRATION -
dc.subject.keywordPlus OPTIMIZATION -
dc.subject.keywordPlus DESALINATION -
dc.subject.keywordPlus REJECTION -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.