File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Microfluidic-based solid phase extraction of cell free DNA

Author(s)
Campos, Camila D. M.Gamage, Sachindra S. T.Jackson, Joshua M.Witek, Malgorzata A.Park, Daniel S.Murphy, Michael C.Godwin, Andrew K.Soper, Steven A.
Issued Date
2018-11
DOI
10.1039/c8lc00716k
URI
https://scholarworks.unist.ac.kr/handle/201301/25282
Fulltext
https://pubs.rsc.org/en/Content/ArticleLanding/2018/LC/C8LC00716K#!divAbstract
Citation
LAB ON A CHIP, v.18, no.22, pp.3459 - 3470
Abstract
Cell-free DNA (cfDNA) is a liquid biopsy marker that can carry signatures (i.e., mutations) associated with certain pathological conditions. Therefore, the extraction of cfDNA from a variety of clinical samples can be an effective and minimally invasive source of markers for disease detection and subsequent management. In the oncological diseases, circulating tumor DNA (ctDNA), a cfDNA sub-class, can carry clinically actionable mutations and coupled with next generation sequencing or other mutation detection methods provide a venue for effective in vitro diagnostics. However, cfDNA mutational analyses require high quality inputs. This necessitates extraction platforms that provide high recovery over the entire ctDNA size range (50 150 bp) with minimal interferences (i.e., co-extraction of genomic DNA), and high reproducibility with a simple workflow. Herein, we present a novel microfluidic solid-phase extraction device (SPE) consisting of a plastic chip that is activated with UV/O-3 to generate surface-confined carboxylic acid functionalities for the SPE of cfDNA. The SPE uses an immobilization buffer (IB) consisting of polyethylene glycol and salts that induce cfDNA condensation onto the activated plastic microfluidic surface. The SPE consists of an array of micropillars to increase extraction bed load (scalable to loads >700 ng of cfDNA) and can be produced at low-cost using replication-based techniques. The entire SPE can be fabricated in a single molding step negating the need for adding additional extraction supports to the device simplifying production and keeping device and assay cost low. The SPE allowed for recoveries >90% of model cfDNA fragments across a range of sizes (100-700 bp) and even the ability to extract efficiently short cfDNA fragments (50 bp, >70%). In addition, the composition of the IB allowed for reducing the interference of co-extracted genomic DNA. We demonstrated the clinical utility of the SPE by quantifying the levels of cfDNA in healthy donors and patients with non-small-cell lung and colorectal cancers. SPE extracted cfDNA from plasma samples was also subjected to a ligase detection reaction (LDR) for determining the presence of mutations in the KRAS gene for colorectal and non-small cell lung cancer patients.
Publisher
ROYAL SOC CHEMISTRY
ISSN
1473-0197
Keyword
CIRCULATING TUMOR DNAPOLYETHYLENE-GLYCOLLUNG-CANCERREVERSIBLE IMMOBILIZATIONCOLORECTAL-CARCINOMAAMERICAN SOCIETYTITER PLATEPURIFICATIONPLASMACONDENSATION

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.