File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

손흥선

Son, Hungsun
Electromechanical System and control Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.number 11 -
dc.citation.startPage 3816 -
dc.citation.title SENSORS -
dc.citation.volume 18 -
dc.contributor.author Park, Chan Sam -
dc.contributor.author Jeon, Jiyun -
dc.contributor.author Oh, Byungjoo -
dc.contributor.author Chae, Hee Young -
dc.contributor.author Park, Kyeonghwan -
dc.contributor.author Son, Hungsun -
dc.contributor.author Kim, Jae Joon -
dc.date.accessioned 2023-12-21T20:07:18Z -
dc.date.available 2023-12-21T20:07:18Z -
dc.date.created 2018-11-07 -
dc.date.issued 2018-11 -
dc.description.abstract This paper presents a portable magnetic induction tomography (MIT) transceiver integrated circuit to miniaturize conventional equipment-based MIT systems. The miniaturized MIT function is enabled through single-chip transceiver implementation. The proposed MIT transceiver utilizes a phase-locked loop (PLL) for frequency sweeping and a phase-domain sigma-delta modulator with phase-band auto-tracking for a full-range fine-phase resolution. The designed transceiver is fabricated and verified to achieve the measured signal to noise and distortion ratio (SNDR) of 101.7 dB. Its system-level prototype including in-house magnetic sensor coils is manufactured and functionally verified for four different material types. -
dc.identifier.bibliographicCitation SENSORS, v.18, no.11, pp.3816 -
dc.identifier.doi 10.3390/s18113816 -
dc.identifier.issn 1424-8220 -
dc.identifier.scopusid 2-s2.0-85056330023 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/25140 -
dc.identifier.url https://www.mdpi.com/1424-8220/18/11/3816 -
dc.identifier.wosid 000451598900226 -
dc.language 영어 -
dc.publisher MDPI AG -
dc.title A Portable Phase-Domain Magnetic Induction Tomography Transceiver with Phase-Band Auto-Tracking and Frequency-Sweep Capabilities -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Chemistry, Analytical; Engineering, Electrical & Electronic; Instruments & Instrumentation -
dc.relation.journalResearchArea Chemistry; Engineering; Instruments & Instrumentation -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor magnetic induction tomography -
dc.subject.keywordAuthor phase-domain sigma-delta modulator -
dc.subject.keywordAuthor phase-locked loop -
dc.subject.keywordAuthor transceiver integrated circuit -
dc.subject.keywordAuthor phase-band auto-tracking -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.