File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

김희령

Kim, Hee Reyoung
RAdiation and MagnetohydroDynamics Advanced Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 2709 -
dc.citation.number 8 -
dc.citation.startPage 2701 -
dc.citation.title INTERNATIONAL JOURNAL OF ENERGY RESEARCH -
dc.citation.volume 42 -
dc.contributor.author Sung, Si Hyeong -
dc.contributor.author Kim, Hee Reyoung -
dc.date.accessioned 2023-12-21T20:40:47Z -
dc.date.available 2023-12-21T20:40:47Z -
dc.date.created 2018-07-07 -
dc.date.issued 2018-06 -
dc.description.abstract The accuracy of a boron meter, which is used to measure the concentration of boric acid, is 1 of the factors affecting operational safety in nuclear reactors. The concept of using a multisensitivity detector to improve the accuracy of the boron meter is proposed, and the accuracy improvement is confirmed by Monte Carlo N-Particle simulation. A Monte Carlo simulation using a multidetector showed a 30 times lower accuracy error (similar to 2ppm) than a single-detector boron meter system (similar to 100ppm). In this study, a new concept of boron meter with improved accuracy is experimentally verified. Experimental verification confirmed that the accuracy was 50% higher than that of the single detector system. To improve the accuracy of the system, the detection efficiency of BF3 detector was measured in boron concentration, source strength, and neutron irradiation time. -
dc.identifier.bibliographicCitation INTERNATIONAL JOURNAL OF ENERGY RESEARCH, v.42, no.8, pp.2701 - 2709 -
dc.identifier.doi 10.1002/er.4059 -
dc.identifier.issn 0363-907X -
dc.identifier.scopusid 2-s2.0-85044314307 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/24332 -
dc.identifier.url https://onlinelibrary.wiley.com/doi/abs/10.1002/er.4059 -
dc.identifier.wosid 000435274300008 -
dc.language 영어 -
dc.publisher WILEY -
dc.title Experimental characterization of the accuracy of multidetector boron meter for operational safety of reactors -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Energy & Fuels; Nuclear Science & Technology -
dc.relation.journalResearchArea Energy & Fuels; Nuclear Science & Technology -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor multidetector -
dc.subject.keywordAuthor BF3 detector efficiency -
dc.subject.keywordAuthor accuracy improvement -
dc.subject.keywordAuthor boron concentration -
dc.subject.keywordAuthor boron meter -
dc.subject.keywordPlus COUNTERS -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.