File Download

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

정모세

Chung, Moses
Intense Beam and Accelerator Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.number 2 -
dc.citation.startPage 022801 -
dc.citation.title PHYSICAL REVIEW ACCELERATORS AND BEAMS -
dc.citation.volume 21 -
dc.contributor.author Seok, Jimin -
dc.contributor.author Chung, Moses -
dc.contributor.author Kang, Heung-Sik -
dc.contributor.author Min, Chang-Ki -
dc.contributor.author Na, Donghyun -
dc.date.accessioned 2023-12-21T21:10:04Z -
dc.date.available 2023-12-21T21:10:04Z -
dc.date.created 2018-03-12 -
dc.date.issued 2018-02 -
dc.description.abstract We report the experimental demonstration of bunch length measurements using a corrugated metallic beam pipe as a passive deflector. The corrugated beam pipe has been adopted for reducing longitudinal chirping after the bunch compressors in several XFEL facilities worldwide. In the meantime, there have been attempts to measure the electron bunch's longitudinal current profile using the dipole wakefields generated in the corrugated pipe. Nevertheless, the bunch shape reconstructed from the nonlinearly deflected beam suffers from significant distortion, particularly near the head of the bunch. In this paper, we introduce an iterative process to improve the resolution of the bunch shape reconstruction. The ASTRA and ELEGANT simulations have been performed for pencil beam and cigar beam cases, in order to verify the effectiveness of the reconstruction process. To overcome the undesirable effects of transverse beam spreads, a measurement scheme involving both the corrugated beam pipe and the spectrometer magnet has been employed, both of which do not require a dedicated (and likely very expensive) rf system. A proof-of-principle experiment was carried out at Pohang Accelerator Laboratory (PAL) Injector Test Facility (ITF), and its results are discussed together with a comparison with the rf deflector measurement. -
dc.identifier.bibliographicCitation PHYSICAL REVIEW ACCELERATORS AND BEAMS, v.21, no.2, pp.022801 -
dc.identifier.doi 10.1103/PhysRevAccelBeams.21.022801 -
dc.identifier.issn 2469-9888 -
dc.identifier.scopusid 2-s2.0-85042234582 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/23838 -
dc.identifier.url https://journals.aps.org/prab/abstract/10.1103/PhysRevAccelBeams.21.022801 -
dc.identifier.wosid 000424633400003 -
dc.language 영어 -
dc.publisher AMER PHYSICAL SOC -
dc.title Use of a corrugated beam pipe as a passive deflector for bunch length measurements -
dc.type Article -
dc.description.isOpenAccess TRUE -
dc.relation.journalWebOfScienceCategory Physics, Nuclear; Physics, Particles & Fields -
dc.relation.journalResearchArea Physics -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.