File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

MitchellRobertJames

Mitchell, Robert J.
Applied and Environmental Microbiology Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Enhanced sensitivity and responses to viologens from a whole-cell bacterial bioreporter treated with branched polyethyleneimines

Author(s)
Mabekou, Sandrine SohLee, S.C.Dinh, T.H.Won, K.Mitchell, Robert J.
Issued Date
2017-12
DOI
10.1111/jam.13592
URI
https://scholarworks.unist.ac.kr/handle/201301/22992
Fulltext
http://onlinelibrary.wiley.com/doi/10.1111/jam.13592/abstract
Citation
JOURNAL OF APPLIED MICROBIOLOGY, v.123, no.6, pp.1478 - 1487
Abstract
Aims: Evaluate the use of polyethyleneimines (PEIs) as membrane permeabilizers to improve the responses and sensitivity of a bacterial bioreporter strain to viologens.
Methods and Results: The responses from E. coli str. EBS, i.e., E. coli BW25113 carrying plasmid pSDS, when exposed to five different viologens were characterized, as were the toxicities of seven different PEIS, including two linear and five branched species. Based on these results, benzyl viologen led to the greatest responses, and 0·8-kDa branched PEI (BPEI) was the least toxic of the PEIs tested and, therefore, both were selected for the subsequent tests. The bioluminescence and relative responses from E. coli str. EBS exposed to various concentrations of 0·8 kDa BPEI identified 400 mg l−1 as the optimal concentration. Using this concentration, tests were performed with all five of the viologens.
Conclusions: The responses from E. coli str. EBS to the viologens were improved, with the maximum relative bioluminescence values increasing between 5·6 and 16·5-fold. The minimum detectable levels for four of the viologens were likewise improved 2- to 4-fold.
Significance and Impact of Study: Improving bacterial membrane permeability in a controlled manner using BPEIs can improve biosensing of toxic compounds, as well as be used in biofuel and bioenergy applications where membrane permeability to a solute is important.
Publisher
WILEY
ISSN
1364-5072
Keyword (Author)
bioluminescencebioreportercell membrane permeabilityE. colipolyethyleneimineviologen
Keyword
MICROBIAL FUEL-CELLSESCHERICHIA-COLIOUTER-MEMBRANEELECTRON-TRANSFEROXIDATIVE STRESSIN-VITROPSEUDOMONAS-AERUGINOSAGENE DELIVERYAGENTSLUX

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.