Effects of interfacial polymerization conditions on performance of polyamide reverse osmosis membranes and optimization of polymerization conditions by statistical methodology

Author(s)
Park, Hyung-GyuJung, Yong-DooHong, Sung-PyoKwon, Young-Nam
Issued Date
2017-05
DOI
10.5004/dwt.2017.20609
URI
https://scholarworks.unist.ac.kr/handle/201301/22316
Fulltext
http://www.deswater.com/vol.php?vol=74&oth=74|0|May|2017
Citation
DESALINATION AND WATER TREATMENT, v.74, pp.1 - 11
Abstract
Effect of fabrication parameters on the performance of polyamide reverse osmosis membrane was systematically investigated and the design of experiment (DOE) method was used as a tool for assessing the degree of contribution of individual parameters on the resultant membrane performance; this was in order to determine the optimized combination of the various parameters. The parametric studies for fabrication included reaction time, temperature of monomer containing solutions, type of organic solvents and monomer concentration. Reaction time controlled the amount of m-phenylenediamine (MPD) diffusing into organic solvents, and the temperature of MPD solution determined the hydrolysis rate of trimesoyl chloride (TMC) taking place exclusively in aqueous phase. Seven organic solvents were investigated to generate various diffusion rate of MPD monomers into the organic solvents, and the thin-film composite (TFC) membranes prepared from higher diffusion rate of MPD into organic solvents showed dense and thinner polyamide layers. Concentration of TMC in organic phase and MPD in aqueous phase showed the effects on the amount of TMC available on the reaction zone and the degree of MPD diffusing across the interface, respectively. Optimum combination of MPD, TMC and aqueous additive concentrations was established with the DOE method for TFC polyamide reverse osmosis (RO) membrane. The reliability of optimum settings for RO membrane preparation condition was verified by confirmation experiments. This study showed that various combinations of monomer concentration for fabrication of RO membranes with tailor-made performance could be provided from DOE and response surface methodology analysis.
Publisher
DESALINATION PUBL
ISSN
1944-3994
Keyword (Author)
PolyamideReverse osmosis membraneInterfacial polymerizationDesign of experiment
Keyword
COMPOSITE NANOFILTRATION MEMBRANESRO MEMBRANESHYPOCHLORITE DEGRADATIONTAGUCHI METHODSURFACECHLORINATIONDESALINATIONBEHAVIORIMPACTSFLUX