File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

신태주

Shin, Tae Joo
Synchrotron Radiation Research Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 12 -
dc.citation.number 1 -
dc.citation.startPage 2 -
dc.citation.title MACROMOLECULAR RESEARCH -
dc.citation.volume 10 -
dc.contributor.author Bolze, Jorg -
dc.contributor.author Kim, Jehan -
dc.contributor.author Huang, Jung-Yun -
dc.contributor.author Rah, Seungyu -
dc.contributor.author Youn, Hwa Shik -
dc.contributor.author Lee, Byeongdu -
dc.contributor.author Shin, Tae Joo -
dc.contributor.author Ree, Moonhor -
dc.date.accessioned 2023-12-22T11:39:35Z -
dc.date.available 2023-12-22T11:39:35Z -
dc.date.created 2015-09-04 -
dc.date.issued 2002-02 -
dc.description.abstract The small-angle X-ray scattering (SAXS) beamline BL4C1 at the 2.5 GeV storage ring of the Pohang Accelerator Laboratory (PAL) has been in its first year of operation since August 2000. During this first stage it could meet the basic requirements of the rapidly growing domestic SAXS user community, which has been carrying out measurements mainly on various polymer systems. The X-ray source is a bending magnet which produces white radiation with a critical energy of 5.5 keV A synthetic double multilayer monochromator selects quasi-monochromatic radiation with a bandwidth of ca. 1.5%. This relatively low degree of monochromatization is sufficient for most SAXS measurements and allows a considerably higher flux at the sample as compared to monochromators using single crystals. Higher harmonics from the monochromator are rejected by reflection from a flat mirror, and a slit system is installed for collimation. A charge-coupled device (CCD) system, two one-dimensional photodiode arrays (PDA) and imaging plates (IP) are available as detectors. The overall performance of the beamfne optics and of the detector systems has been checked using various standard samples. While the CCD and PDA detectors are well-suited for diffraction measurements, they give unsatisfactory data from weakly scattering samples, due to their high intrinsic noise. By using the IP system smooth scattering curves could be obtained in a wide dynamic range. In the second stage, starting from August 2001, the beamline will be upgraded with additional slits, focusing optics and gas-filled proportional detectors -
dc.identifier.bibliographicCitation MACROMOLECULAR RESEARCH, v.10, no.1, pp.2 - 12 -
dc.identifier.doi 10.1007/BF03218282 -
dc.identifier.issn 1598-5032 -
dc.identifier.scopusid 2-s2.0-0002451764 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/16642 -
dc.identifier.url http://link.springer.com/article/10.1007/BF03218282 -
dc.identifier.wosid 000175295000001 -
dc.language 영어 -
dc.publisher POLYMER SOC KOREA -
dc.title Current status of the synchrotron small-angle X-ray scattering station BL4C1 at the Pohang Accelerator Laboratory -
dc.type Article -
dc.description.journalRegisteredClass scopus -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.