File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

최은미

Choi, EunMi
THz Vacuum Electronics and Applied Electromagnetics Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Experimental observation of the effect of aftercavity interaction in a depressed collector gyrotron oscillator

Author(s)
Choi, EunMiShapiro, M. A.Sirigiri, J. R.Temkin, R. J.
Issued Date
2007-09
DOI
10.1063/1.2776911
URI
https://scholarworks.unist.ac.kr/handle/201301/10879
Fulltext
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=34848814099
Citation
PHYSICS OF PLASMAS, v.14, no.9, pp.1 - 5
Abstract
This paper presents the experimental observation of the effect of an aftercavity interaction (ACI) in a depressed collector gyrotron oscillator. The gyrotron generates an output power of 1.5 MW at 110 GHz in 3 μs pulses with a 96 kV and 40 A electron beam and has a single-stage depressed collector. The ACI arises from an unintended cyclotron resonant interaction between the microwave beam traveling out from the cavity and the gyrating electron beam. The interaction occurs in the uptaper of the launcher, immediately downstream from the cavity, where the magnetic field is slightly lower than its value in the cavity region. The ACI results in a reduction in efficiency since the electron beam tends to extract power from the wave. There is also a broadening of the spent beam energy profile, which reduces the effectiveness of the depressed collector and in turn limits the overall efficiency of a gyrotron. Measurements of the maximum depression voltage of the collector vs beam current at 96 kV are compared with simulations from the MAGY code [M. Botton, IEEE Trans. Plasma Sci. 26, 882 (1998)]. Excellent agreement is obtained between theory and experiment but only if the ACI is included. In the present experiment, it is estimated that the observed efficiency of 50% would have been about 60% in the absence of the ACI. These results verify the role of the ACI in reducing the efficiency of the gyrotron interaction.
Publisher
AMER INST PHYSICS
ISSN
1070-664X
Keyword
ELECTRONS

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.